SG(B) series 11, 12, 13 unencapsulated H-class dry-type power transformer

SG(B) series 11, 12, 13 unencapsulated H-class dry-type power transformer

Advantage

> Clean production environment

> Full automatic testing with various tests

> Standardized production process with trained workers

> Low failure ratio and 24-month warranty

> Strong R&D and engineering support

Request a Quote  
SG(B) series 11, 12, 13 unencapsulated H-class dry-type power transformer

         The main insulating material of the SG(B)10 Un-packed "H" Level power transformer is an insulating system based on Nomexpaper. The HV & LV coils were insulated by Nomex pater. It has been vacuum immersed by "H" level Non-solvent insulation paint and treatd by high temperature. lt can be kept in and excellent electronic and mechanical features during the whole transformer' s life. Due to the Nomex is not easy to ageing,withstand contraction and anti-press,the coil of the transformer will be still com-pact and withstand the pressure of short circuit after several years operating. The no-load loss is 20% and 25% lower than thel specification in GB10228-2015. lt is a kind of environmental product,which has a low loss and low voice. lt has beenl widely used in subway,high building,airports and any other places.

 

 

Ordering instruction

Please provide the following parameters when ordering:

1. Product model 

2. Rated capacity 

3. Voltage combination

4. Adjustment range 

5. Frequency 

6. Connection symbd

7. Short-circuit impedance

8. Please note the technical requirements for the products having the special requirements

​Rated current (A) Voltage combination and tapping range Linkage group No-load current (%) No-load loss (W) Load loss (W) Short-circuit impedance (%)
High voltage (KV) High pressure tap range % Low voltage (KV)
100

6

6.3

10.5

11

±2*2.5

±5

0.4

Dyn11

Yyn10

1.60 400 1690  
125 1.50 470 1980
160 1.40 540 2280
200 1.30 620 2710
250 1.20 720 2960
315 1.10 880 3730
400 1.00 980 4280
500 1.00 1160 5230
630 0.90 1340 6290
630 0.90 1300 6400 6.0
800 0.80 1520 7460
1000 0.70 1770 8760
1250 0.60 2090 10370
1600 0.60 2450 12580
2000 0.60 3050 15560
2500 0.50 3600 18450

 

Message Feedback
If you have any enquiry about quotation or cooperation,please free to email us at Winston or use the following enquiry form,Our sales representative will contact you within 24 hous.thank you for your interest in our products.
News Center
How can I test the foot switch after install?
To test a foot switch after repair, follow these steps:1. Visual Inspection: Check for any visible damage or loose parts. Make sure all components are correctly placed and secured。2. Connectivity Chec
2024-09-27
Can I repair a damaged foot switch myself?
Repairing a damaged foot switch can be a straightforward process if you have some basic knowledge of electrical systems and the necessary tools. Here are some steps you can follow to repair a foot swi
2024-09-27
Winston Exhibition
nverter, maybe everyone knows that there is such a thing and what it is used for, but
2024-04-25
Chinese frequency inverter manufacturer mainly introduced to you what is an inverter
Inverter, maybe everyone knows that there is such a thing and what it is used for, but if you introduce it to others, most of you may not know how to say it. Because there are many things we know in life but don’t understand it. Of course, I believe that people who understand electricity or decoration industries still know about frequency converters. Next, the Chinese frequency inverter manufacturer mainly introduces to you what is an inverter.
2024-04-22

GET A QUOTE

AFFORDABLE PRICE: AS A MANUFACTURER, WE GIVE YOU FACTORY PRICE
Contact Us For Free Sample
×